For every item, SV500 reports the failure impact and the electrical indicators it uses, so engineers can check the reasoning behind each alert.

SV500 monitors three-phase induction motors. Failure impacts and diagnostic indicators are listed below.

Input voltage

Failure impact
Equipment malfunction, accelerated motor degradation
Diagnostic indicators
Voltage RMS, crest factor, voltage imbalance, THD

Rotor

Failure impact
Higher vibration and noise, accelerated bearing wear
Diagnostic indicators
Current spectrum frequencies, static and dynamic eccentricity frequencies

Stator

Failure impact
Lower efficiency, phase imbalance, heat, vibration and noise
Diagnostic indicators
Park vector analysis, current spectrum, current imbalance

Noise and vibration

Failure impact
Electrical and mechanical stress, reduced insulation and structural integrity
Diagnostic indicators
Noise bands in voltage and current spectra, spectral instability

Overheating

Failure impact
Motor degradation, shorter life, lower efficiency
Diagnostic indicators
RMS current, harmonic and distortion indices, DC components

Cable connections

Failure impact
Higher resistance, voltage drop, overheating, arcing
Diagnostic indicators
Phase current imbalance, resistance imbalance

Bearings

Failure impact
Higher vibration and noise, stator-rotor contact damage
Diagnostic indicators
Rolling and journal bearing defect frequencies

Torque ripple

Failure impact
Higher vibration and noise, accelerated bearing wear
Diagnostic indicators
Positive and negative sequence components, torque stability